Hot and cold shock test box

brief introduction

Haun series cold and hot impact test chamber is the necessary test equipment for metal, plastic, rubber, electronic and other material industries. It is used to test the degree of endurance of material structure or composite material under the continuous environment of extremely high temperature and extremely low temperature, so as to detect the chemical change or physical damage caused by thermal expansion and cold contraction in a short time. The cold and hot shock test chamber meets the following test methods: GB /, GB / t10592-2008, high and low temperature impact test.



阀体

purpose

It is used in electronic and electrical components, automation parts, communication components, auto parts, metals, plastics and other industries. It is used to test the physical changes of national defense IC, semiconductor ceramics and polymer materials. The product quality can be confirmed by testing the repeated resistance of the materials to high and low temperature, and the chemical changes or physical damage of the products during thermal expansion and cold contraction, From Precision IC to heavy machinery components, all need its ideal testing tools.

Main technical parameters

Environmental conditions: the ambient temperature is + 5 ~ + 28 ℃, the relative humidity is less than 85%, and there is no sample in the test chamber (i.e. no load)

Test methods: GB / T 2423.1-2001, GB / T 2423.2-2001, GB / T 2423.22-2001, GJB 150.3-2001

Specification and model he-lr-80s

Inner tank capacity 80 l

Inner box size width 500 × height 400 × depth 400 (mm)

Overall dimensions: width 1500 × height 1850 × depth 1500 (mm)

The total weight of the equipment is about 600kg

Use AC three-phase five wire 380V, 50Hz

The total power is about 23KW

Two partition frames (bearing 20kg)

High temperature region: RT (normal temperature) ~ + 180 ℃

2. Low temperature area: RT (normal temperature) ~ - 65 ℃

Temperature test range 1. High temperature + 60 ℃~ + 150 ℃

2. Low temperature: - 10 ℃~ - 40 ℃

High and low temperature conversion time ≤ 10s

Recovery time of high and low temperature is 3-5min (under nonlinear no-load condition)

Resolution ±℃

Control accuracy ±℃

Temperature deviation ±℃

Heating rate of preheating zone ≤ 30 minutes

Cooling rate of precooling area ≤ 80 minutes

Temperature exposure time: 30 minutes in high temperature area and 30 minutes in low temperature area

Standard basis

1. GB / low temperature test method;

2、GB/;

3. GB / temperature change test n;

4. -86;

5. GJB150.4-86;

6. GJB15-86;

7. Gjb15-86 temperature shock test;

8. Temperature shock test;

9. Gjb367.2-87 405 temperature impact test;

10. SJ / t10187-91y73 series temperature change test chamber - one box type;

11. SJ / t10186-91y73 series temperature change test chamber -- two box type;

12. Meet the standard iec68-2-14_ Test method n_ Temperature change;

10. GB / T 2424.13-2002 test methods - temperature change test guidelines;

11. GB / T 2423.22-2002 temperature change;

12. QC / t17-92 general rules for weathering test of auto parts;

13. EIA 364-32 thermal shock (temperature cycling) test procedure for electrical connectors and sockets.

Precautions for use

1. Try to avoid shutting down and starting the refrigeration unit within three minutes to avoid affecting the function of the compressor

2. It is forbidden to heat or test the explosive and combustible substances which are highly corrosive. Otherwise, it will cause unnecessary loss, or the machine can not test it

3. The amount of test objects should not affect the air circulation of the test box, otherwise the performance of the machine will be affected

4. When using, the door should be closed tightly, otherwise the temperature will leak out and the performance area will not be reached

5. Assign personnel to operate the machine to avoid early damage to the machine

6. When the machine is running, it is necessary to avoid opening the box door as far as possible, because when the temperature is low, it is easy to open the box door to cause ice sealing phenomenon in the internal evaporator and other parts. Especially, the lower the temperature is, the more serious the situation is. If it must be opened, the time should be shortened as far as possible.

7. When the operation is completed, open the door to take the test object after the machine stops completely.

8. During operation, please do not open the door unless it is necessary, otherwise it may lead to the following adverse consequences: high temperature gas flushes out of the box Very dangerous!

The inside of the door remains high and low Cause damage!

High temperature air may trigger fire alarm and cause malfunction!

Door opening method: the operator must move backward along the opening direction when opening the door to prevent a large amount of hot air gushing out to hurt people

9. Please note that the machine must be grounded safely to avoid static induction!

10. Circuit breaker and over temperature protector provide the safety protection of the tester and the operator, so please check it regularly.

11. During operation, please do not touch it by hand to avoid electric shock or fan injury, which may cause danger. Therefore, please stop the operation and turn off the power before repairing.

12. Non staff members are not allowed to maintain and inspect the machine. During the maintenance and inspection, it should be carried out by full-time personnel, and at the same time, there should be monitoring personnel to prevent the uninformed personnel from electrifying and closing, which may cause electric shock and injury.

Maintenance method

1. The condenser (radiator) of refrigeration unit shall be maintained regularly and kept clean. Dust sticky condenser will make the compressor high-pressure switch trip off and cause false alarm. The condenser should be regularly maintained every month. Dust attached to the condenser heat dissipation mesh should be removed by using a vacuum cleaner or cleaned with a hard brush or blown with a high-pressure air nozzle after starting up.

2. When opening or closing the door or taking the test object from the furnace, do not let the object contact with the rubber edge on the door, so as to prevent the rubber edge from being damaged and shorten the service life.

3. The ground around and at the bottom of the fuselage should be kept clean at any time, so as to avoid accidents and reduce performance caused by large amount of dust inhaled into the unit.

4. The refrigeration system is the core of the machine. Please inspect all copper pipes for leakage and snow every half a year. If there is oil leakage in the mouthpiece joints and welding joints, please inform our company or deal with it directly.

5. The large current contact of the distribution board should be cleaned and overhauled at least once a year in the distribution room. If the contact is loose, the whole equipment will be in a dangerous working state. In light of this, the components will be burnt out, and the fire, alarm and personal injury will be very dangerous. When cleaning, the dust in the room can be removed by using a vacuum cleaner.

6. Please do not adjust the setting values of the two over temperature protectors in the distribution box. They have been adjusted at the factory. This protection switch is used to protect the heating pipe from empty combustion and alarm. Set point = temperature set point + 20 ℃ ~ 30 ℃.

7. When the test product time arrives, the product must be taken off and the staff must wear dry, electricity proof and temperature resistant gloves

8. Cleaning and maintenance of the inside and outside of the box.

9. The internal impurities should be removed before operation.

10. The power distribution room should be cleaned at least once a year. When cleaning, please use the vacuum cleaner to remove the indoor dust. The outside of the box must be cleaned more than once a year, and it can be cleaned with soapy water.

Recently Viewed:

Bozhong YOUPU

Contact person: Mr. Wang

Tel: 0512-52972252

Email: W wang@szypco.com

website: www.szypco.com

Address: No.10 WengZhuang Road, Shanghu Town, Changshu, Suzhou, Jiangsu Province



Bozhong YOUPU

Online Message

Focus on us

Pay attention to us